• Inquiry(0)
  • JUN AN ELECTRONIC CO., LTD.
    JUN AN ELECTRONIC CO., LTD.
    • Inquiry ()
    • About Us
    • Products
      • Emtest
        • Automotive EMC Test Solutions ISO7637
        • ESD Generators
        • EMS Compact Generators
        • Voltage Surge Generators
        • Conducted LF/RF Immunity Testing
        • Telecom Surge Generators
        • Harmonics & Flicker
      • PPST
        • PACIFIC POWER SOURCE
          • AMX Series
          • ACX Series
          • ASX Series
          • AFX Series
          • MS Series
          • G Series
        • APS
          • AC & DC Loads
          • AC & AC Sources
          • APS Software
        • STS
          • Battery Element Testers
          • Model 1740 Test System
        • ZENONE
          • GI Series
          • GI -SI Series
          • GIS Series
          • GV Series
          • GTS Series
          • FVC Series
          • AL3000 Series
          • AL3000R Series
      • Weetech
        • Low Voltage Cable Test
        • High Voltage Cable Test
        • Backplane/Chassis Test
        • Functional Test
      • BONN
        • BSA Series
        • BLMA Series
        • BLWA Series
      • KAST
    • Hot Products
    • News
    • Contact Us
    • Site Map
    • 駿安電子
    > Products » Emtest » EMS Compact Generators » Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

    Products

      • Automotive EMC Test Solutions ISO7637
      • ESD Generators
      • EMS Compact Generators
      • Voltage Surge Generators
      • Conducted LF/RF Immunity Testing
      • Telecom Surge Generators
      • Harmonics & Flicker
      • PACIFIC POWER SOURCE
        • AMX Series
        • ACX Series
        • ASX Series
        • AFX Series
        • MS Series
        • G Series
      • APS
        • AC & DC Loads
        • AC & AC Sources
        • APS Software
      • STS
        • Battery Element Testers
        • Model 1740 Test System
      • ZENONE
        • GI Series
        • GI -SI Series
        • GIS Series
        • GV Series
        • GTS Series
        • FVC Series
        • AL3000 Series
        • AL3000R Series
      • Low Voltage Cable Test
      • High Voltage Cable Test
      • Backplane/Chassis Test
      • Functional Test
      • BSA Series
      • BLMA Series
      • BLWA Series
    • Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)
    • Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)
    • Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

    Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

    •As per IEC 61000-4-5 Ed.3, Fig 10/A4, ITU K.44
    •For test pulse 1.2/50 - 8/20µs and 10/700µs
    •Coupling via gas arrestor or other coupling
    •Built-in matching resistors
    •20mH decoupling, current compensated pairs
    •Test voltage up to 5kV
    •Line voltage 50V
    •Line current 1A
    Model : CNV 504 / 508 T-Series

    • Description
    • Specifications
    • Features
    • Applications


    CNV 504 / 508 T-series - Coupling decoupling networks for unshielded communication lines

    Surge pulses and Telecom Surge pulses are applied to unshielded symmetrical interconnection lines (communication lines) by means of standalone coupling/decoupling networks. CNV 504T5 is designed for 4 lines (2 pairs), CNV 508T5 for 8 lines (4pairs) and can also be used for either 4 or 2 lines. 

    According to IEC 61000-4-5 Ed.3, (Fig. 10) the pulses are coupled via gas arrestors and a matching resistor per line.
     
    • As per IEC 61000-4-5 Ed.3, Fig 10/A4, ITU K.44

    • For test pulse 1.2/50 - 8/20µs and 10/700µs

    • Coupling via gas arrestor or other coupling

    • Built-in matching resistors

    • 20mH decoupling, current compensated pairs

    • Test voltage up to 5kV

    • Line voltage 50V

    • Line current 1A


    Surge 1.2 /50us

    CNV 504 / 508 T-series - Surge coupling/decoupling networks for communication lines


    The EM TEST CNV 504 / 508 T-series coupling/ decoupling networks are designed to couple Surge pulses (1.2/50us - 8/20us) and Telecom Surge pulses (10/700us) onto unshielded symmetrically operated communication lines. 

    The CNV-models includes the coupling via gas arrestor plus the internal matching resistor Rc as per figure 10 of IEC 61000-4-5 Ed.3 with values as per the formula given by the standard. All lines are subjected to the test pulse simultaneously with respect to ground.

    The CNV also include the required decoupling part consisting of decoupling inductors of 20mH for each line, pairwise current compensated. To further protect the auxiliary equipment being needed for testing the DUT an additional protection circuit is integrated at the communication line input.



    Surge 10/700 us


    CNV 504 / 508 T-series - Telecom Surge coupling/decoupling networks for communication lines


    The CNV 504 / 508 T-series is also designed as per figure A4 of IEC 61000-4-5 Ed.3 without primary protector. If required, an additional primary protector must be integrated according the user specifications.

    With short circuit bridges and individual designed coupling devices the user can easy modify the coupling mode and number of tested lines to the requirements.


     EM TEST offers CNV 504 / 508 T-series coupling/decoupling networks for test voltages up to 5kV.

    EN 61000-4-5
    IEC 61000-4-5
    ITU-T K.44

    Related Products

    Combined 1-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

    Combined 1-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

    Multifunctional test generator for transients (EFT/Burst, Surge & Power Fail) up to 5.5 kV

    Multifunctional test generator for transients (EFT/Burst, Surge & Power Fail) up to 5.5 kV

    Combined 3-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

    Combined 3-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

    Electrical Fast Transient Generator

    Electrical Fast Transient Generator

    Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

    Coupling/decoupling network for unshielded symmetrical interconnection lines (communication lines)

    Combined 3-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

    Combined 3-phase coupling/decoupling networks for Burst and Surge testing up to 10kV

    JUN AN ELECTRONIC CO., LTD.

    About Us  |  Products  |  Hot Products  |  News  |  Contact Us  |  Privacy Policy
    Tel:886-2-22120182          Fax:886-2-29237718
    Email:junan@jun-an.com.tw
    Address:7F., NO.57, SEC. 2, YONGHE RD., YONGHE DIST., NEW TAIPEI CITY 23444, TAIWAN (R.O.C.)

    © 2026 JUN AN ELECTRONIC CO., LTD. All rights reserved. Made in Taiwan 網路行銷

    This site uses cookies to collect the necessary user browsing behavior so that we can provide you with a better browsing experience. Browse this site, which means you agree with "online privacy declaration."
    × Close